Konfort Series 700R Service Manual
4.5.5 "NEW OIL" calibration on Konfort 760R, 760R Bus e 780R

BiGas

The New Oil function, available in the Sensor calibration menu, allows
user to calibrate the auxiliary load cell for the oil injection on the
equipment.
Refer to the procedure reported on Paragraph 4.5.3 for the calibration of
the auxiliary load cell for the drained oil. When requested, place the
appropriate sample weight to the oil injection plug on the back of the
unit:
Image 4.80 – Connection of the 400-grams sample
4.5.6 "MAIN SENSOR" calibration on Konfort 760R, 760R Bus and
780R BiGas
The Main sensor function, available from the Sensor calibration menu,
allows user to calibrate the main pressure sensor of the equipment.
Copyright © 2014 – TEXA S.p.A.
weight to the plug of the oil injection
81
TEXA Technical Assistance