The Unit Does Not Inject Oil - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual
In case of Konfort 705R, 710R or 720R units, check that the liquid
outlet of the oil and UV injection bottles will be present and that it
will not suck air.
In case of Konfort 760R, 760R Bus and 780R BiGas units, ensure that
the inner membrane of the oil and UV injection bottles will not be
damaged or punctured:
Image 7.27 – Check of the integrity of the inner membrane
7.6

The unit does not inject oil

Check that the oil quantity inside the bottle will be sufficient.
In case of Konfort 705R, 710R or 720R units, check that the liquid
outlet of the bottle will be present and that it will be immersed into
the oil.
In case of Konfort 705R, 710R or 720R units, ensure that the liquid
outlet of the oil bottle will not be obstructed.