Oil Drain; Vacuum - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual

2.2.2 Oil Drain

During this phase, the equipment activates the following electrical
components:
EVSO electro-valve;
1
Load cell (8)
.
After the recovery phase, the equipment opens the exhaust oil EVSO
electro-valve for the time necessary to empty the bottom of the separator
filter from the oil and the impurities collected during the recovery phase
from the A/C system of the vehicle. The discharge is helped by the
residual pressure inside the equipment.
Image 2.3 – Part of the hydraulic circuit involved into the oil drain phase

2.2.3 Vacuum

During this phase, the equipment activates the following electrical
components:
Pressure sensor (1);
LP electro-valves (only for 760R, 760R Bus and 780R BiGas);
HP electro-valves (only for 760R, 760R Bus and 780R BiGas);
EVP01 and EVP02 electro-valves;
Vacuum pump PO;
Heating band.
1
Component available only on 760R, 760R Bus and 780R BiGas models
Copyright © 2014 – TEXA S.p.A.
TEXA Technical Assistance
13

Advertisement

Table of Contents
loading

Table of Contents