4.4
The "SENSOR CALIBRATION" function on K705R, K710R and
K720R
By selecting the feature called Sensor calibration in a Konfort 705R,
710R and 720R, the following page of the Service menu will be
displayed:
R e f r i g e r a n t
U V
A d d i t i v e
N e w
O i l
M a i n
Image 4.17 – The first page of the Sensor Calibration function
of the Service menu in a Konfort 705R, 710R and 720R
S e c o n d a r y
Image 4.18 – The second page of the Sensor Calibration function
of the Service menu in a Konfort 705R, 710R and 720R
Now the calibration procedures for each individual sensor of the Konfort
705R, 710R and 720R units will be passed in review.

4.4.1 "REFRIGERANT" calibration on K705R, K710R and K720R

The Refrigerant function, available in the Sensor Calibration menu,
allows to calibrate the refrigerant load cell of the equipment.
In order to proceed with the calibration, the user must first of all remove
the front panel of the Konfort unit and release the cylinder from the
scale, in order to easily make the steps required during the calibration
procedure.