Too Much Oil And/Or Uv Additive Is Injected - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual
In case of Konfort 760R, 760R Bus and 780R BiGas units, check the
airtight of the o-ring into the upper cap (see Image 7.28) and of the
one located on the inner container with deformable membrane (see
Image 7.29). In case, replace the two o-rings.
In case of Konfort 760R, 760R Bus and 780R BiGas units, ensure that
the black cap on the top of the bottle (removable in case of need to
refill the bottle itself) will be intact and hermetic. In case, proceed
with the replacement of the cap.
In case of Konfort 760R, 760R Bus and 780R BiGas units, check, from
the Power outputs menu, the linearity of the UV injection load cell.
If necessary, proceed with the calibration of the load cell. In case
that the calibration will not be successful, replace the load cell.
In case of Konfort 760R, 760R Bus and 780R BiGas units, ensure that
the quick connector of the oil bottle will not be obstructed (refer to
Image 7.30). In case that the connector would be obstructed, replace
the entire top part of the bottle.
Check the path of the silicone tube which connects the bottle to the
manifold of the equipment (see Image 7.26), and verify its integrity.
Ensure that the EVUV solenoid valve, responsible of the UV injection,
will work properly, by manually activating it from the Power outputs
menu.
In case of Konfort 710R or 720R units, ensure that the UV bottle will
be fully connected. If necessary, replace the quick connector of the
bottle itself.
7.8

Too much oil and/or UV additive is injected

Check that the tube which connects the bottle to the manifold will
allow the free movement of the load cell (see Image 7.26). If
necessary, restore its correct position.