Konfort Series 700R Service Manual
4.7.5 List of the public parameters for Konfort 760R Bus
VESSEL TARE MAIN TANK
VESSEL TARE SECOND TANK
MAX RELATIVE WEIGHT MAIN TANK
MAX RELATIVE WEIGHT SECOND TANK
NEW OIL TARE
UV TARE
USED OIL TARE
USED OIL MAX WEIGHT AT START
USED OIL MAX WEIGHT
AIR EVACUATION TIME FOR GAS ANALYZER
GAS HEATING VACUUM MINIMUM TIME
VESSEL RECHARGE OFFSET WEIGHT
STOP COMPRESSOR THRESHOLD
USED OIL PHASE THRESHOLD
FILLING PHASE DEFAULT WEIGHT
VACUUM DEFAULT TIME
LEAK TEST DEFAULT TIME
ADJUST HP TUBE LENGTH
ADJUST LP TUBE LENGTH
ADJUST LP-HP TUBE LENGTH
PRESSURE TRANSDUCER OFFSET
PRESSURE CONTROL DEFAULT TIME
GAS HEATING TIME (0=AUTO)
OIL DEFAULT QUANTITY
UV DEFAULT QUANTITY
VACUUM TIME STANDARD
VACUUM CHECK POINT DEFAULT TIME
FLUSHING DEFAULT TIME
REPLACEMENT FILTER MAX WEIGHT
REPLACEMENT OIL PUMP MAX TIME
RESTART COMPRESSOR THRESHOLD
LEAK TEST THRESOLD
NOT ENOUGH VACUUM THRESHOLD
UV/NEW OIL PHASE THRESHOLD
BOTTLE CHECK MODE
FAN CHECK MODE
VACUOMETER OFFSET
DEBUG ON SD CARD 0=OFF, 1=ON
Table 4.11 – List of the public parameters for Konfort 760R Bus
Copyright © 2014 – TEXA S.p.A.
PARAMETER
94
TEXA Technical Assistance
DEFAULT
VALUE
gr. 24000
gr. 0
gr. 30000
gr. 0
gr. 310
gr. 310
gr. 270
gr. 200
gr. 250
msec. 500
min. 10
gr. 600
mbar. 920
mbar. 920
gr. 800
min. 20
min. 4
gr. 30
gr. 0
gr. 30
mbar. 30
min. 2
sec. 0
ml. 10
ml. 5
min. 20
min. 10
sec. 30
hg. 1500
min. 5400
mbar. 1600
mbar. 120
mbar. 50
mbar. 400
mbar. 0
2
1
0