The Equipment Does Not Switch On - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual
7.2

The equipment does not switch on

If the equipment is connected to an extension cable, remove it.
Check the voltage of the network power supply plug (~ 230V - 50Hz)
of the place where the equipment is operating.
Open the cap of the network filter (use a 2-millimiters Allen wrench,
press the two plastic tongues above and below the cap and pull it
out) and, with the switch of the unit set in "ON" position, check the
voltage (~ 230V - 50Hz) by placing the probes of a multimeter on the
blue and brown wires:
Image 7.1 – Removal of the cap of the network filter on Konfort 720R, 760R,
Image 7.2 – Check the voltage (~ 230V - 50Hz)
Copyright © 2014 – TEXA S.p.A.
760R Bus and 780R BiGas
between the blue and the brown wires