The Auxiliary Load Cells Are Not Properly Calibrated; The Main Pressure Sensor Is Not Properly Calibrated - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual
conditions, the weight value would not change, replace the mechanic
part of the scale.

7.13 The auxiliary load cells are not properly calibrated

Make sure that all the steps of the auxiliary load cells calibration have
been carefully followed (refer to the information reported on Chapter
4 regarding these calibration processes).
Use always the 400-grams sample weight provided by TEXA S.p.A.
Remove the bottle from the back of the equipment. Check from the
Power outputs menu that, when the sample weight is inserted, the
value of the corresponding load cell will be increased. If not, replace
the corresponding auxiliary load cell.

7.14 The main pressure sensor is not properly calibrated

Ensure that all the steps of the main pressure sensor calibration have
been carefully followed (refer to the information reported in Chapter
4 for this calibration).
Ensure that the cable which connects the pressure sensor to the ACE
Micro board will
properly inserted into the corresponding connector.
Remove the HP connector from the corresponding service pipe, open
the HP valve (in the case of Konfort 705R, 710R or 720R) or the HP
solenoid valves from the Power outputs menu (in case of Konfort
760R, 760R Bus and 780R BiGas unit). Blow, with compressed air,
into the HP tube and ensure, from the Power outputs menu, that
the pressure measured by the main sensor will increase. Otherwise,
proceed with the replacement of the sensor.
14
Only on Konfort 760R, 760R Bus and 780R BiGas units
Copyright © 2014 – TEXA S.p.A.
not be damaged and that all its wires will be
152
TEXA Technical Assistance
14