Image 7.34 (B) – Weight value of the oil injection load cell
with the sample weight (first image) and without sample weight
(second image): the load cell has a linear behavior
If the auxiliary load cell would continue to show a non-linear
behavior, proceed with its calibration. If, despite this process, the
problem will persist, proceed with the replacement of the load cell.
7.9

The equipment does not inject refrigerant

Ensure that the service pipes will be properly connected to the A/C
system of the vehicle and that the two quick fittings will be open.
In case of Konfort 705R, 710R and 720R units, ensure that both the
HP and LP valves located on the side panel of the equipment will be
open.