Digital Input/Output - Planet IGS-10020 Series User Manual

L2+ multi-port full gigabit managed ethernet switch
Hide thumbs Also See for IGS-10020 Series:
Table of Contents

Advertisement

4.2.16 Digital Input/Output

Digital Input allows user to log external device (such as industrial cooler) dead or alive or something else. System will log a
user customized message into system log and syslog, and issue SNMP trap or issue an alarm E-mail.
Digital Output allows user to monitor the switch port and power, and let system issue a high or low signal to an external device
(such as alarm) when the monitor port or power has failed. The Configuration screen in
The page includes the following fields:
Object
Enable
Condition
Figure 4-2-18 Windows File Selection Menu Popup
Description
Check the Enable checkbox to enable Digital Input / output function.
Uncheck the Enable checkbox to disable Digital input / output function.
As Digital Input:
Allows user to select High to Low or Low to High. This means a signal received
by system is from High to Low or From Low to High. It will trigger an action that
logs a customize message or issue the message from the switch.
As Digital Output:
Allows user to select High to Low or Low to High. This means
switch is power-failed or port-failed, then system will issue a High or
Low signal to an external device such as an alarm.
96
User's Manual
Figure 4-2-18
appears.
that when the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Igs-10080mftIgs-12040mtIgs-20040mtIgs-20160hpt

Table of Contents