Table 5-1 Maintenance tools
Item
Phillips screwdriver (No.2)
Torx driver (T10)
Wrist strap
ESD mat
5.2
Switching the Mode Switch to Service
Mode
Note - The mode switch on the operation panel does not need to be changed in active
maintenance.
1.
Switch the mode switch on the operation panel to Service mode.
For details, see
5.3
Checking the Operating Condition and
Resource Usage Status
This section describes the checking of the operating condition of the logical domain
and the resource usage status before maintenance is performed on each FRU.
5.3.1
Checking the operating condition of the physical
partition or logical domain
In the following execution example, the operating condition of the physical partition
and logical domain is checked from firmware.
1.
Log in to the XSCF shell.
2.
Execute the showpparstatus command to confirm the operating condition of
the physical partition.
In the following example, [PPAR Status] of PPAR-ID 00 displays "Running",
which indicates that the physical partition is operating.
46
Fujitsu M10-1/SPARC M10-1 Service Manual ・ June 2021
Use
For removing or installing screws
For removing or installing screws
For static grounding
For static grounding
"2.3.2 Control function of the operation