XSCF
XCP1 (Reserve): 2011
CMU
XSCF
CMU BACKUP
#0: 02.01.0001
#1: ..
XSCF>
6.3.3
When the system is configured with a hardware
RAID
If you have replaced the motherboard unit in a hardware RAID configuration,
activate the RAID volume.
1.
Log in to the XSCF shell.
2.
Execute the setpparparam command to suppress auto-boot.
XSCF> setpparparam -p 0 -s bootscript "setenv auto-boot false"
Start the system.
3.
For details, see
4.
The ok prompt appears.
5.
Enable the RAID volume to check the status.
For details, see "14.2.11 Re-enabling a Hardware RAID Volume" in the Fujitsu
SPARC M12 and Fujitsu M10/SPARC M10 System Operation and Administration
Guide.
Stop the system after returning the Auto boot setting to the original one.
6.
{0} ok setenv auto-boot? true
XSCF> poweroff -a
6.4

Diagnosing a Replacement FRU

This section describes the diagnosis function for checking whether a replacement
80
Fujitsu M10-1/SPARC M10-1 Service Manual ・ June 2021
POST
: 1.20.0
OpenBoot PROM : 4.34.0+1.2.0
Hypervisor
: 0.21.11
: 02.01.0001
: 02.00.0006 (*2)
POST
: 1.13.0
OpenBoot PROM : 4.34.0+1.0.5
Hypervisor
: 0.21.3
: 02.01.0001
"6.9 Starting the
System."