Table 7-7 System-stopped/hot replacement work procedure (for an internal disk)
Item
Work procedure
1
Opening the rack door
2
Switching the mode switch on the
operation panel to Service mode
3
Checking the operating condition of the
system and the I/O device usage status
4
Stopping the system
5
Replacing a faulty FRU
6
Diagnosing the replacement FRU
7
Confirming that there is no problem with
the replacement FRU
8
Returning the mode switch on the
operation panel to Locked mode
9
Starting the system
10
Closing the rack door
System-stopped/cold replacement
System-stopped/cold replacement can be performed on the following FRUs:
PCI Express card
■
Motherboard unit
■
Memory
■
Internal disk
■
Fan unit
■
Power supply unit
■
PSU backplane
■
HDD backplane
■
Operation panel
■
Cable kit
■
Perform the following procedure to replace the unit.
Reference
"5.2 Switching the Mode Switch to Service
"5.3 Checking the Operating Condition and Resource
Usage
Status"
"5.5 Stopping the Entire
"Chapter 9 Maintaining the Internal
"6.4 Diagnosing a Replacement
"6.7 Checking the FRU Status after
"6.8 Returning the Mode Switch to Locked
"6.9 Starting the
System"
Mode"
System"
Disks"
FRU"
Maintenance"
Mode"
Chapter 7 Maintenance Flow
101