Table 7-7     System-stopped/hot replacement work procedure (for an internal disk)
Item
Work procedure
1
Opening the rack door
2
Switching the mode switch on the
operation panel to Service mode
3
Checking the operating condition of the
system and the I/O device usage status
4
Stopping the system
5
Replacing a faulty FRU
6
Diagnosing the replacement FRU
7
Confirming that there is no problem with
the replacement FRU
8
Returning the mode switch on the
operation panel to Locked mode
9
Starting the system
10
Closing the rack door
System-stopped/cold replacement
System-stopped/cold replacement can be performed on the following FRUs:
PCI Express card
Motherboard unit
Memory
Internal disk
Fan unit
Power supply unit
PSU backplane
HDD backplane
Operation panel
Cable kit
Perform the following procedure to replace the unit.