which the entire system is stopped.
Each of the above two maintenance types is further divided into the two types of hot
maintenance and cold maintenance.
Hot maintenance
Type of maintenance performed with the power cords connected to the chassis
requiring maintenance
Cold maintenance
Type of maintenance performed with the power cords removed from the chassis
requiring maintenance
3.2

Active Maintenance

The type of maintenance performed with Oracle Solaris operating on the physical
partition is referred to as active maintenance. Note that active/cold maintenance is
not supported on the SPARC M10-1.
Table 3-2
Table 3-2     Whether active maintenance (replacement/addition/removal) is enabled for
FRU
PCIe card
Internal disk
HDD backplane
Power supply unit
PSU backplane
Cable kit
Operation panel
Fan unit
Motherboard unit
Memory
*1 Active/hot maintenance can be performed on the PCIe cards mounted in the PCI expansion unit. For details,
see "3.3 Types of Maintenance for the PCIe Card" in the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu
M10/SPARC M10 Service Manual.
*2 Supported only for the internal disks of devices other than a boot device. However, if the boot device has a
redundant configuration (RAID configuration), active/hot maintenance can be performed on the internal disks of
the boot device.
*3 If the XSCF startup mode is high-speed mode, hardware cannot be replaced using the replacefru command.
Perform system-stopped (inactive)/cold maintenance.
26
Fujitsu M10-1/SPARC M10-1 Service Manual ・ June 2021
shows whether active maintenance is enabled for each FRU.
each FRU
-: Maintenance cannot be performed.
Active/hot maintenance
- (*1)
OK (*2)
-
OK (*3)
-
-
-
OK
-
-
Reference
(*1)
Chapter 9
Chapter 11
Chapter 15