Moving the feed-dog carrier in the sewing direction
Figure 27: Moving the feed-dog carrier cross-line to the sewing direction
(1) - Tie rod connecting screws
(4) - Assembly frame
(5) - Plates
15.Position the upper stitch length adjusting wheel to 0.
16.Loosen the clamping screw (14).
17.Align the assembly frame such that the plates (5) are parallel to one
18.Tighten the clamping screw (14).
19.Move the feed-dog carrier in the sewing direction such that it is exactly
20.Tighten the rear assembly frame screw (6).
21.Tighten the connection to the tie rod using the screws (1).
22.Attach the tension spring (8) back in the mounting bracket.
36
another.
in the center of the throat plate cut-out.
Important: In the process, make sure that the feed-dog height has the
correct setting (
height in the top dead center, page 38).
(6) - Assembly frame screw
(8) - Tension spring
(14) - Clamping screw
Section 9.2.2 Setting the feed-dog