Installation
8.5

Escape release

8.5.1

Important information

}
The button of the escape release pin must be impossible to reach from a position outside
the protected area.
}
Prevent any unintended operation of the escape release.
}
Prevent the effect of transverse forces on the escape release.
}
Secure the screw connections with a medium-strength threadlocker.
}
The button of the escape release pin must be clearly visible and it must not be concealed.
}
Maintain the min. bending radius of the push/pull cable of 60 mm when using the external
escape release.
}
The mounting surface has to completely cover the bottom of the escape release housing.
The bottom of the escape release housing must not be accessible after installation.
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
WARNING!
Risk of injury due to loss of the safety function.
Incorrect installation of the escape release means that the button of the es-
cape release pin can be accessed from the outside. This can entail that the
guard locking is unlocked from the outside and the safety gate is opened,
although the hazardous machine is switched on.
– The escape release should be installed so that it is only accessible
from inside the danger zone.
NOTICE
Functional restrictions of the external escape release imposed by in-
correct installation
On escape releases with push/pull cables 0.5 m (order no. 570466) and
0.75 m (order no. 570467), bending the push/pull cable may reduce its func-
tionality and lifetime.
Ensure that these versions are installed as straight as possible.
| 49