Installation
Maintain a slight shift of the rotation point of the door when installing the actuator.
Legend
}
Tilt the actuator by 10° when installing, when the door radius is R < 600 mm.
Pilz recommends that you use the PSEN ml actuator 10° adapter for correctly installing
the actuator.
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
R The distance of the upper part of the safety switch from the rotation point of the
door
X Parallel shift of the actuator
α Tilt angle when installing the actuator
| 41