Installation
8.4.5

Centre the bolt in the actuator housing

The bolt must be centred in the actuator housing in order to maintain the distances on set-
tling gates.
With small door radiuses, the bolt should be centred in the actuator housing.
Centre the bolt in the actuator housing (see diagram). Use the PSEN ml actuator cen-
ter ring only with small door radiuses (see
gate [
Bolt centred within the actu-
ator housing
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
40]).
NOTICE
Reduction of the actuator's service life
When using the accessory PSEN ml actuator center ring the actuator's ser-
vice life can be substantially reduced.
After 50.000 cycles it may happen that the actuator misaligns, and that it
has to be realigned regularly.
Bolt not centred within the actuator
housing
Install the safety switch horizontally at a swing
Bolt with PSEN ml actuator center
ring in the actuator housing