Pilz PSEN ml s 1.1 Operating Manual page 12

Table of Contents

Advertisement

Overview
}
LEDs:
– Supply voltage/fault
– Status of actuator
– Status of guard locking
– Input lights up yellow (without function)
}
The bolt in the actuator can be rotated 90° in the actuator housing before the actuator is
installed. As a result, the actuator can be installed vertically or horizontally.
}
The safety switch can be expanded with up to three stationary and/or external escape re-
leases (see
The stationary escape release can be extended by a maximum of 50 mm (twice by
25 mm).
The external escape releases are available with push/pull cables with a length of between
0.5 and 4 m (50 cm increments).
}
On small door radiuses, (see
gate [
Accessories [
}
The actuator is available in two types (see
– Standard actuator
– Actuator with rounded tip
Standard actuator
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
Order reference: Accessories [
Install the safety switch horizontally at a swing
40]) the PSEN ml actuator center ring can be inserted (see
83]).
83]).
Order reference: Accessories [
Actuator with rounded tip
Order reference:
83]).
| 12