Error Display - Pilz PSEN ml s 1.1 Operating Manual

Table of Contents

Advertisement

Operation
10.2

Error display

LED status
Device
Safety Gate
Red
Yellow
Previous LED display is
retained
Red
Red
Display not definitive
Red
Green
Yellow
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
Input
Lock
Display not
Safety switch de-
definitive
activated due to
under or over-
voltage
Yel-
low
Display not
Safety outputs in
definitive
fault condition
Auxiliary release/
escape release
activated
Red
Safety switch
does not start
Display not
Wrong actuator
Dis-
definitive
play
not
defin-
itive
Switch status
Check the supply voltage and
switch the supply voltage off and
then on again.
Check the wiring and switch the
supply voltage off and then on
again.
}
Auxiliary release: Turn back the
auxiliary release screw and then
switch the supply voltage on (see
Recommissioning [
}
Escape release: Pull the button of
the escape release pin back
again and then switch on the sup-
ply voltage again (see Recommis-
sioning under escape release).
Change the safety switch.
Use only approved combinations
(see
Approved
combinations [
Remedy / measure
23]).
11])