  • Page 1 PSEN sl-0.5p 2.1/2.2 PSEN sensor technology Operating Manual-1003820-EN-03...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    Teaching in the actuator PSEN sl-0.5p 2.1 PSEN sl-0.5p 2.2 Installation Note regarding the free-moving actuator PSEN sl-0.5fm Installing on a swing gate Installing on a sliding gate Adjustment Operation Error display through flashing codes Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 4 Contents Dimensions in mm Technical Details Order No. 570501-570502 Technical Details Order No. 570561-570562 Supplementary data Radio approval Safety characteristic data Order reference Order reference for safety gate system Accessories EC declaration of conformity Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 5: Introduction

    PSEN sl-0.5p 2.1/2.2 Introduction Validity of documentation This documentation is valid for the product PSEN sl-0.5p 2.1/2.2. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6: Safety

    The following is deemed improper use in particular: Any component, technical or electrical modification to the product Use of the product outside the areas described in this manual Use of the product outside the technical details (see Technical details [ 27]). Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 7: Safety Regulations

    Are familiar with the basic regulations concerning health and safety / accident preven- tion, Have read and understood the information provided in this description under "Safety" Have a good knowledge of the generic and specialist standards applicable to the spe- cific application. Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 8: Warranty And Liability

    Do not remove the connector's protective cap until you are just about to connect the unit. This will prevent potential contamination. Unit features Transponder technology for presence detection Device types Pilz coding type: – PSEN sl-0.5p 2.1: fully coded – PSEN sl-0.5p 2.2: uniquely coded different actuators available (see Order reference [ 34]) –...
  • Page 9: Function Description

    The actuator is outside the response range or There is a low signal at the inputs S11 or S21 or There is a low signal at the input S31 (control command for magnetic guard locking) or Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 10: Lateral And Vertical Offset

    Therefore a higher effort is required when opening for the first time. If the safety gate is in a locked condition and is opened by force, the safety outputs will shut down. Lateral and vertical offset Max. vertical offset: 5 mm Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 11: Wiring

    Set the supply voltage constantly to the upper tolerance range (see Technical details: System with normal actuator [ 27], System with free-moving actuator [ 30]). Select a higher conductor cross section Reduce load at the outputs, e.g. with evaluation device PNOZ e1.1p Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 12: Recommended Cable Cross Sections

    Cable type: LiYY 8x0.25 mm² (79 Ohm/km) from Pilz Max. load per safety output 100 mA 500 mA Cable length 65 m 28 m If cable lengths greater than those stated in the table are required, please contact Pilz. Pin assignment 8-pin M12 connector Cable colour (Pilz Function Terminal designation cable)
  • Page 13: Connection To Evaluation Devices

    Make sure that the selected evaluation device has the following properties: 2-channel with feasibility monitoring OSSD signals are evaluated Connection diagram, single connection 24 V Actuator Safety switch O1 (ST) I1 (FS) I2 (FS) Evaluation device FS: Failsafe ST: Standard Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 14 Connection diagram, series connection 24 V O1 (ST) Safety switch Actuator I1 (ST) O2 (ST) Safety switch Actuator I2 (ST) O3 (ST) Safety switch Actuator I3 (ST) I1 (FS) I2 (FS) Evaluation device FS: Failsafe ST: Standard Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 15 When several units are connected in series, the required current adds with the number of interconnected safety switches. The safety switch PSEN sl-0.5p 2.1/2.2 can be connected to Pilz evaluation devices, for ex- ample. Suitable Pilz evaluation devices are, for example:...
  • Page 16: Connection Example Pnoz S3

    PSEN sl-0.5p 2.1/2.2 Connection example PNOZ s3 PNOZ s3 PSENslock Connection example PNOZmulti PNOZmulti PSENslock green yellow grey Output element, PNOZmulti Legend: Input OSSD Input OSSD Signal input Lock/Unlock Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 17: Teaching In The Actuator

    System with free-moving actuator [ 30], under mechanical data) is automatically taught in as soon as it is brought into the response range. NOTICE No other actuator may be taught in once this actuator has been taught. Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 18: Psen Sl-0.5P 2.1/2.2

    (e.g. cheese-head or pan head screws) or rivets. Alignment errors of the guard must not adversely affect the safety function of the guard. INFORMATION Mounting brackets are available as accessories [ 34]. Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 19: Note Regarding The Free-Moving Actuator Psen Sl-0.5Fm

    The actuators enable a warped gate to be closed. A gap may occur on the gate as a result. Make sure that the gap remains small enough to exclude the possibility of reaching into the danger zone. Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 20: Installing On A Swing Gate

    Close gate. Align the mounting bracket flush with the safety switch and tighten the screws. Align the safety switch and mounting bracket with the actuator and tighten the screws. Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 21: Installing On A Sliding Gate

    Align the safety switch mounting bracket flush with the frame and fasten with screws. (Important: do not tighten the screws) Fix safety switch upright with a screw (a), close gate. Align mounting brackets, press firmly together and tighten screw (b). Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 22: Adjustment

    The safety functions may only be checked by qualified personnel. CAUTION! Contaminated surfaces can reduce the holding force of the locking magnet. Make sure that the contact surfaces are clean. Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 23: Error Display Through Flashing Codes

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Decimal error code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 Example: Error code 1,4,1: Flash frequency of the "Safety Gate" or "Input" LED Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 24 Check cable length and too high (cable is shorten it, if necessary (see too long) max. cable length) Other flashing codes signal an internal error. Remedy: Change device. Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 25: Dimensions In Mm

    PSEN sl-0.5p 2.1/2.2 Dimensions in mm M12x1 Fig.: Safety switch and locking magnet 22,5 Fig.: Actuator Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 26 PSEN sl-0.5p 2.1/2.2 Fig.: Mounting bracket for sliding gate (see Accessories [ 34]) 11,5 54,5 Fig.: Mounting bracket for swing gate (see Accessories [ 34]) Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 27: Technical Details Order No. 570501-570502

    Short circuit-proof Residual current at outputs 250 µA 250 µA Voltage drop at OSSDs 1,5 V 1,5 V Conditional rated short circuit cur- rent 100 A 100 A Lowest operating current 0 mA 0 mA Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 28 In accordance with the standard EN 60068-2-27 EN 60068-2-27 Number of shocks Acceleration Duration 11 ms 11 ms In accordance with the standard EN 60068-2-27 EN 60068-2-27 Number of shocks Acceleration Duration 16 ms 16 ms Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 29 44 mm Actuator dimensions Height 138 mm 138 mm Width 52 mm 52 mm Depth 23 mm 23 mm Weight of safety switch 570 g 570 g Weight of actuator 375 g 375 g Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 30: Technical Details Order No. 570561-570562

    Semiconductor outputs 570561 570562 OSSD safety outputs Signal outputs Switching current per output 500 mA 500 mA Breaking capacity per output 12 W 12 W Short circuit-proof Residual current at outputs 250 µA 250 µA Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 31 EN 55011: class A, EN 60947-5-3, EN 62061 EN 62061 Vibration In accordance with the standard EN 60947-5-2 EN 60947-5-2 Frequency 10 - 55 Hz 10 - 55 Hz Amplitude 1 mm 1 mm Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 32 LiYY 8 x 0.25 mm2 Material Anchor plate Nickel-plated steel Nickel-plated steel Base plate Anticorodal, hard anodised Anticorodal, hard anodised Actuator Anticorodal, hard anodised Anticorodal, hard anodised Max. torque setting for fixing screws 3 Nm 3 Nm Operating Manual PSEN sl-0.5p 2.1/2.2 1003820-EN-03...
  • Page 33: Supplementary Data

    2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 34: Order Reference

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PSEN sl-0.5p 2.1/2.2...
  • Page 35 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...

This manual is also suitable for:

Psen sl-0.5p 2.2

Table of Contents