Function description
4.7
Prevent restart
To prevent the machine restarting (unintentionally) while there is someone inside the
danger zone, the actuator can be secured using padlocks (see diagram). As a result the ac-
tuator cannot engage with the safety switch, guard locking is not activated and the machine
is prevented from starting.
}
Minimum 2, maximum 6 padlocks
}
Padlock bow diameter
– ≤ 6 mm with maximum 6 padlocks
– ≤ 7 mm with maximum 3 padlocks
Legend
[1]
[2]
[3]
4.8
Escape release
The actuator PSEN ml DHM enables manual release of guard locking via an escape re-
lease handle. The escape release handle is inside the danger zone. So the actuator corres-
ponds to an escape release in accordance with EN ISO 14119.
4.8.1
Recommissioning
1. Reset the handle.
2. Switch the voltage off and then on again.
3. Carry out a function test using the escape release. The safety function may only be
checked by qualified personnel.
Operating Manual PSEN ml b 1.1/2.1/2.2, PSEN ml DHM
1005444-EN-02
INFORMATION
If the auxiliary release screw is not turned back correctly after use, the
safety switch switches to a fault condition.
[1]
Actuator PSEN ml DHM
Flap on the actuator PSEN ml DHM for attaching the padlocks
Padlock
[2]
[3]
| 20