Troubleshooting - Assa Abloy Norton 5700P Series Installation Instructions Manual

Power operator with optional plug-in power input pull and push side
Hide thumbs Also See for Norton 5700P Series:
Table of Contents

Advertisement

5700P Series Power Operator
ON
1
2
In Toggle Setting (1-ON), Hold
Time is inactive. Either setting
for #2 dip switch will have
same result.
Description
#1
OFF
Pulse Relay
ON
Toggle Relay
#2
Description
OFF
0.5s Hold Time
ON
10s Hold Time
NOTE:
Always stop pedestrian traffic through doorway when
performing tests that may result in unexpected reactions
by door.
Ensure compliance with all applicable safety standards
upon completion of installation.
Hand-Held Configuration
1.
Set dip switches to receiver to desired activation cycle (dip
switch 1 - Toggle or Pulse and dip switch 2 - 0.5s or 10s
hold).
2.
Press either Learn w/ Delay Button or Learn w/o Delay
Button on receiver depending on activation requirements
(if delay learn is selected, adjust potentiometer to
counterclockwise limit, 0 second delay). Red LED on
receiver will flash. After learn cycle is complete, adjust
potentiometer to desired delay time (0 - 30 sec).
3.
Depress transmitter button repeatedly until Blue LED on
receiver illuminates (indicating reception of signal from
transmitter).
NOTE: Repeat Steps 2 - 3 to program additional
transmitters.
4.
To test system, depress transmitter button (Red LED on
Transmitter will illuminate) and observe that Blue LED
illuminates on receiver. This indicates that relay has been
activated.
Problem
LED on receiver is flickering - unable to
program and/or won't work
Receiver intermittently doesn't receive
transmitter(s) signal.
Copyright © 2016, 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9357-0009-020 Rev 7 01/20
433MHz Receiver User's Guide
ON
ON
1
2
1
2
0.5 second
Pulse Setting
Function
Press transmitter once and relay will be active momentarily.
Press transmitter once and relay output is active indefinitely.
Press it again and relay will de-energize indefinitely.
Function
Relay will remain active 0.5 sec after loss of activation.
Relay will remain active 10 sec after loss of activation.
Push plate stuck or faulty transmitter. Disconnect each push plate until LED goes
out. If LED does not go out, remove each transmitter battery until it does. Replace
appropriate transmitter.
Extend receiver antenna wire only in multiples of 6-3/4" (171)
Example: 6.75 x 4 = 27" (686) of extended antenna wire.
Approved 2020-01-27
ON
1
2
Terminal
10 second
Pulse Setting
Strip
Push Plate Configuration
1.
Before beginning, prepare installation of push plate.
2.
Connect wires from transmitter to NO and COM contacts of
push plate's switch.
3.
Follow Steps 1 - 4 (Hand-Held Configuration); depress push
plate to activate transmitter.
4.
Attach transmitter to inside of electrical box and complete
installation.
Removing Transmitter Code(s)
Single Transmitter Code:
Press both Delay and No Delay Buttons simultaneously until
Red LED flashes once (approximately 1 second).
Press transmitter button twice within 10 seconds and
transmitter code will be deleted.
All Transmitter Codes:
Press and hold both Delay and No Delay Buttons
simultaneously until Blue LED illuminates then release
(approximately 10 seconds).

Troubleshooting

Solution
Antenna Wire
Blue LED
Learn
w/o Delay
DIP Switch
Button
Delay
Learn w/
Potentiometer
Delay Button
(Time Adjustment)
Red LED
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton 5710Norton 5730Norton 5740

Table of Contents