Adjustments - Assa Abloy Norton 5700P Series Installation Instructions Manual

Power operator with optional plug-in power input pull and push side
Hide thumbs Also See for Norton 5700P Series:
Table of Contents

Advertisement

5700P Series Power Operator

Adjustments

A. Adjust mechanical closer features.
NOTE:
Make necessary mechanical adjustments so
unit functions as a standard surface mounted
door closer before adjusting spring force,
applying power, adding accessories or making
electrical/programming adjustments.
Refer to table for recommended minimum
opening/closing times per ANSI/BHMA
A156.19. (Figure 24)
Use hex wrench to make adjustments.
Do not remove valves from closer.
Hydraulic oil will escape.
1.
Closing Speed Controls (Figure 22)
• Valve "S" controls Sweep Range from
full open to 10°.
• Valve "L" controls Latch Range from
10° to closed.
2.
Opening Cycle (Figure 23)
• Valve "BC" controls strength of cushioning in
Backcheck Range.
NOTE: Too much backcheck can affect
operation of unit pump, preventing full
open of door. This valve may require fine
tuning after all other adjustments have been
made.
B. Adjust spring force.
NOTE:
The amount of effort to manually open or
close a door is called force and is controlled by
the operator's closer spring.
Make necessary mechanical adjustments
described in "A" above.
A closer set to ADA required 5 lbs opening
force may not be strong enough to close door
due to latching hardware, air pressure, or
frame issues.
1.
Using 1/8" hex wrench, turn power adjustment
screw clockwise to increase door closing power.
(Figure 25)
NOTE: Door control is shipped set at midpoint
of power setting. Maximum closing power can
be achieved with 8 (360°) clockwise turns of
power adjustment screw.
Copyright © 2016, 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9357-0009-020 Rev 7 01/20
Approved 2020-01-27
Latch
Sweep
10°
A.D.A. requires that from an open position of
70°, door will take at least 3 seconds to move
to a point 3" (75mm) from latched position,
measured at leading edge of door.
Figure 22
ANSI/BHMA A156.19 Minimum Opening/Closing Times
Door Leaf
Width
100
- Inches (mm)
(45.4)
30" (762)
3.0 sec
36" (914)
3.0 sec
42" (1067)
3.5 sec
48" (1219)
4.0 sec
Backcheck: Adjust backcheck to have minimum opening time to backcheck or 80
degrees (whichever comes first) based on Table.
Closing Time: Adjust latch and sweep to have minimum closing time from 90
degrees to latch check or 10 degrees (whichever comes first) based on Table.
Figure 24
Power Adjustment
Figure 25
Backcheck
10°
75°
Figure 23
Door Weight - Pounds (kg)
125
150
175
(56.7)
(68.0)
(79.4)
3.0 sec
3.0 sec
3.0 sec
3.5 sec
3.5 sec
4.0 sec
4.0 sec
4.0 sec
4.5 sec
4.5 sec
4.5 sec
5.0 sec
200
(90.7)
3.5 sec
4.0 sec
4.5 sec
5.5 sec