Wiring - Assa Abloy Norton 5700P Series Installation Instructions Manual

Power operator with optional plug-in power input pull and push side
Hide thumbs Also See for Norton 5700P Series:
Table of Contents

Advertisement

Operation:
Door is normally closed and latched.
Activating switch will cut power to mag
lock and door will automatically open.
Door will close after hold open time
delay has elapsed.
Door will unlock during power failure.
NOTE:
1.
Power input to Door Operator Unit
is at "T1" Power Input Terminal (not
shown) 120VAC 60Hz.
2.
Unit Relay Rating: 30VDC @ 1A or
125VAC @ .5A
3.
Door must be visible by person
operating activation switch(es).
Jumper Settings:
Place jumper to upper position for normally
closed operation or to lower position for
normally open operation.
Operation:
Door is normally closed and latched.
Activating switch will unlock electric
strike and door will automatically open.
Door will close after hold open time
delay has elapsed.
For Fail Secure Strike - door will remain
locked during power failure.
For Fail Safe Strike - door will remain
unlocked during power failure.
NOTE:
1.
Power input to Door Operator Unit
is at "T1" Power Input Terminal (not
shown) 120VAC 60Hz.
2.
Unit Relay Rating for strike interface:
30VDC @ 1A or 125VAC @ .5A
3.
Door must be visible by person
operating activation switch(es).
Jumper Settings:
Place jumper to upper position for normally
closed operation or to lower position for
normally open operation.
16
Fail Safe Electromagnetic Lock 24VDC Wiring
Fail Secure/Fail Safe Electric Strike Wiring
Copyright © 2016, 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in
whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2020-01-27
5700P Series Power Operator
80-9357-0009-020 Rev 7 01/20