Troubleshooting - Assa Abloy SW60 Installation And Service Manual

Swing door operator
Hide thumbs Also See for SW60:
Table of Contents

Advertisement

14 Troubleshooting

14
Troubleshooting
Fault
The door does not open
The motor does not start
LED light blinks
The motor starts but the
door does not open
The door does not close
46
Possible reasons why
Control switch is set to OFF
Mains power is missing
Door is in error
Mechanical lock is locked
Something jammed beneath the door
Electric striking plate is binding
Arm system has come loose
Control switch is set to HOLD
Something jammed beneath the door
Issue 2020-10-27
Remedies/Explanations
Change the setting of the control switch
Check the mains power and fuse in the building
Remove power, wait 10 seconds. Re-introduce
power and test door functions.
Unlock the lock
Remove object
Select lock release
Adjust striking
Tighten the arm system by installation steps
Change the setting of the control switch
Remove object
1020004-en-US-2.0