Troubleshooting - Assa Abloy Norton SafeZone 7110SZ Installation And Instruction Manual

Table of Contents

Advertisement

Sensing Field Adjustments
THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL AND LATERAL ANGLE OF THE ANTENNA
Sensing field as close to the door as possible:
-antenna set at the position of 0°
Hold Time Settings
Hold open time refers to the time the
door will remain open AFTER
movement is no longer detected.
Hold open time can be adjusted
manually by means of the push
buttons + (more) and - (less).
Setting
Time (Seconds)
0
1
2
3
4
5
(Default)
6
7
8
9

Troubleshooting

SYMPTOMS
Red LED does not light up.
(No power to sensor)
Door Stops several times in
the same cycle without
sensing presence in the door
way.
Door not closing when cover
installed.
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
A
Sensing field close to the door:
-antenna set at the position of 30°
0.5
Recommended Settings:
5
6
7
8
10
14
16
18
20
PROBABLE
CAUSE
Power switch is off.
Loose wire connection.
Sensitivity is set too high
Eye is sensing the closer
cover.
B
30º
Sensing field far from the door:
-antenna set at the position of 45°
Setting 1-3
CORRECTIVE
ACTION
Turn power switch to "ON" position.
Inspect wiring for loose connections.
Change sensitivity setting using
optional remote.
Adjust the sensing field away from
cover edge. (See "Sensing Field
Adjustments" above.
13
C
45º
+ Press and release button
to increase hold open
setting (do not hold
button continuously).
(see table below)
-
Press and release button
to decrease hold open
setting (do not hold
button continuously).
Example: If the current setting is 5 and the
required setting is 8, press and release the button
3 times.
Setting 4-6
ASSA ABLOY
3000 Highway 74 East • Monroe, NC 28112
Tel: (877)-
974-2255
www.nor tondoorcontrols.com
80-9371-0081-020 (01-14)
ASSA ABLOY
-30º
+30
Pressing the two push
buttons, located on the
circuit board,
simultaneously for three
seconds, will restore all
default settings.
Setting 7-9