Electrical Installation; Power Input (Tb101); Figure 2-1: Power Input Connections; Table 2-1: Power Supply Wiring (Tb101) - Aerotech Ensemble QLe Series Hardware Manual

Table of Contents

Advertisement

Installation and Configuration

2.2. Electrical Installation

The Ensemble QLe has one AC input power connector. For a complete list of electrical specifications, refer
to
Section 1.1. Electrical

2.2.1. Power Input (TB101)

AC input power to the QLe is applied to the Input Power (TB101) connector.
The connection requires a minimum of 100 VAC input to operate properly. The AC1 and AC2 inputs are
internally fused.
Figure 2-1
Table 2-1:
Power Supply Wiring (TB101)
Pin
Description
AC1
100 - 240 VAC Input Range
AC2
100 - 240 VAC Input Range
Protective Ground (Required for Safety)
Type
3-Pin Terminal Block
20
Specifications.
shows the required connections to the control power input.
POWER INPUT
AC1
AC2
100-240V~
Figure 2-1:
Power Input Connections
Aerotech P/N
ECK00213
Chapter 2
Ensemble QLe Hardware Manual
TB101
50/60Hz
2A MAX
Screw Torque
Phoenix P/N
Value: Nm
1754465
0.5 - 0.6
Recommended Wire Size
2
1.3 mm
(#16 AWG)
2
1.3 mm
(#16 AWG)
2
1.3 mm
(#16 AWG)
Wire Size:
2
AWG [mm
]
12-30 [3.3 - 0.516]
www.aerotech.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ensemble qle500-cEnsemble qle250-c

Table of Contents