Changing the IP address of the Remote Power Supply Rack
Shelf
In an environment where there are multiple Remote Power Supply Rack Shelf devices, you must have
a unique IP address for each device.
1. Select Communications > Configure Communication Parameters.
2. Set the new IP address for the Remote Power Supply Rack Shelf.
3. Click Submit Changes.
After the IP address has been changed from the web interface, close the browser window and
then open it using the new IP address.
If you have changed the IP address of the Remote Power Supply Rack Shelf, the IP address
and subnet mask of the computer must also be changed.
Resetting the Remote Power Supply Rack Shelf IP address
The Remote Power Supply Rack Shelf IP address ensures local access with a laptop and a standard
network crossover cable.
Press and hold the front panel reset button (RST) for three seconds.
The Remote Power Supply Rack Shelf beeps three times, the IP address is reset to
10.10.10.201, and DHCP is disabled.

Changing the time on the Remote Power Supply Rack Shelf

Configure the time on the Remote Power Supply Rack Shelf.
The date and time is a dynamic field, and as changes are made to the values on the screen the
internal values are also changed. An event is added to the event log detailing the changes made.
1. Log in to the Remote Power Supply Rack Shelf web interface.
2. Select Controller > Date and Time.
3. Set the date and time for the Remote Power Supply Rack Shelf.
Manually enter the date and time for the Remote Power Supply Rack Shelf to use.
Automatically retrieve the date and time from a server.
a. Select Enable SNTP Service.
b. Type the IP address of the SNTP source.
c.
In the Time Zone Adjustment field, select the time zone adjustment for the location
of the Remote Power Supply Rack Shelf.
4. Click Save.
5. If the time is set by an SNTP service, click Get Time Now.

Setting the temperature units

Change the units used when reporting the temperature.
1. Log in to the Remote Power Supply Rack Shelf web interface.
2. Select Controller > Temperature Units.
3. Select whether the display units are Celsius or Fahrenheit.
Velvet LED Display System Installation and Setup Guide–Apex A2L Series