Configure the Connect IT Mini
Setting
Enable
Interface type
Zone
Device
Match SIM by
Match SIM slot
Digi Connect IT® Mini User Guide
Description
Select Enable to enable the network interface.
The address configuration method for the network interface.
Modem: The address is determined by the cellular
n
modem.
The default is Modem.
The firewall zone assigned to this network interface. This can
be used by packet filtering rules and access control lists to
restrict network traffic on this interface.
The default is External.
The modem used by this network interface.
The default is Modem.
The match criteria to apply when determining if this
interface should be used.
Any SIM: Apply this interface to the modem with any
n
SIM.
SIM slot: Apply this interface when a specified
n
SIM slot is active. An entry in the Match SIM slot field
is required.
Carrier: Apply this interface with SIM cards from a
n
particular cellular carrier. An entry in the Match SIM
carrier field is required.
PLMN identifier: Apply this interface with SIM cards
n
that have a specific PLMN identifier. An entry in the
Match PLMN identifier field is required.
IMSI: Apply this interface with SIM cards that have a
n
specific IMSI. An entry in the Match IMSI field is
required.
ICCID: Apply this interface with SIM cards that have a
n
specific ICCID. An entry in the Match ICCID field is
required.
This conditional field displays when the SIM slot option is
selected from the Match SIM by list box.
Enter the SIM slot match criteria. The interface is applied
when the modem is using this SIM slot. Modems with a single
SIM slot will always match SIM1.
The default value is SIM1.