Mitsubishi Electric FR-D720-0.1K Instruction Manual page 123

Hide thumbs Also See for FR-D720-0.1K:
Table of Contents

Advertisement

Setting
Signal
Positive
Negative
logic
logic
70
170
SLEEP PID output interruption
80
180
SAFE
Safety monitor output
81
181
SAFE2
Safety monitor output 2
90
190
Y90
Life alarm
Fault output 3
91
191
Y91
(power-off signal)
Current average
93
193
Y93
monitor signal
Maintenance timer
95
195
Y95
signal
96
196
REM
Remote output
98
198
LF
Alarm output
99
199
ALM
Fault output
9999
No function
∗1
Note that when the frequency setting is varied using an analog signal or
alternate ON and OFF depending on that varying speed and the timing of the varying speed due to acceleration/deceleration time setting.
(The output will not alternate ON and OFF when the acceleration/deceleration time setting is "0s".)
REMARKS
The same function may be set to more than one terminal.
When the function is executed, the terminal conducts at the setting of any of "0 to 99", and does not conduct at the setting of
any of "100 to 199".
NOTE
Changing the terminal assignment using Pr.190, Pr.192, and Pr. 197 (output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Do not assign signals which repeat frequent ON/OFF to A, B, and C. Otherwise, the life of the relay contact decreases.
Refer to pages 21, for the common terminal of each terminal.
Function assignment of external terminal and control
Function
Output when the PID output interruption function is
executed.
Output while safety stop function is activated.
Output while internal safety circuit fault (E.SAF, E.CPU) is
not activated.
Output when any of the control circuit capacitor, main
circuit capacitor and inrush current limit circuit or the
cooling fan approaches the end of its service life.
Output when a fault occurs due to the internal circuit failure
or the inverter wiring mistake, etc.
Average current value and maintenance timer value are
output as pulses.
The signal can not be set in Pr. 192 A,B,C terminal function
selection .
Output when Pr. 503 rises to or above the Pr. 504 setting.
Output to the terminal when a value is set to the parameter.
Output when an alarm (fan failure or communication error
warning) occurs.
Output when a fault occurs.
The signal output is stopped when the fault is reset.
Operation
of the operation panel, the output of the SU (up to frequency) signal may
Refer
Related
to
Parameter
Page
Pr. 127 to Pr.
134,
211
Pr. 575 to Pr.
577
27
27
Pr. 255 to
228
Pr. 259
123
Pr. 555 to
233
Pr. 557
Pr. 503,
232
Pr. 504
Pr. 495, Pr.
127
496
Pr. 121,
182,
Pr. 244
227
123
4
121