Connector Pinouts - Extreme Networks BlackDiamond 10808 Hardware Installation Manual

Extreme blackdiamond 10808: installation guide
Hide thumbs Also See for BlackDiamond 10808:
Table of Contents

Advertisement

Technical Specifications
Table 15: Specifications for the DC SSI PS Model #60021 (1200 W DC PSU) (Continued)
Input
Output
Operating conditions

Connector Pinouts

Table 16
describes the pinouts for a DB-9 console plug connector.
Table 16: Pinouts for the DB-9 Console Connector
Function
DCD (data carrier detect)
RXD (receive data)
TXD (transmit data)
DTR (data terminal ready)
GND (ground)
DSR (data set ready)
RTS (request to send)
CTS (clear to send)
136
Nominal input voltage: –48 V
Voltage input range: –40.5 V
Input currents:
–40 V
@ 35 A
–48 V
@ 30 A
–60 V
@ 23 A
Maximum in-rush current: Not more than 80 A for 5 ms
Input circuit protection: 50 A
Wire harness provided by Extreme Networks with each power supply.
Extreme Part# 4340-00028
Wire type: 8 AWG (10 mm
minimum
Connector: Molex connector PN 42816-0312
Connector pins: Molex connector pins PN 42815-0032
DC output: 48 V
, 24 A / 12 V
DC output power (W): 1200 W
Operating temperature: 0° C to 40° C (32° F to 104 °F)
Operating humidity: 10% to 90% relative humidity, non-condensing
Operating altitude: 0 m to 3,000 m (0 ft to 9,850 ft)
Operational shock*: 30 m/s
Operational office vibration*: 5 to 100-5 Hz @ 2/10 G, 0 to peak, 1 oct/min
Operational random vibration*: 3 to 500 Hz @ 1.5 G rms
* Worst case operational condition; not for continuous operation under this
condition
Pin Number
Direction
1
In
2
In
3
Out
4
Out
5
-
6
In
7
Out
8
In
to –72 V
2
) listed tray cable, copper-stranded rated @ 90 C
, 4 A
2
(3 g), 60 shocks
BlackDiamond 10808 Switch Hardware Installation Guide

Advertisement

Table of Contents
loading

Table of Contents