3.0 Setup

When the remote is connected to a Magnum inverter/charger, the settings in
the remote control determine the inverter/charger operating parameters. The
default settings in the remote control (see Table 3-4, Inverter/Charger Default
Settings) are adequate for most installations, however you have the option to
change some of the operating parameters if required. This section will show
you how to navigate the remote, give you an understanding of the function of
each adjustable setting, and help you decide what setting should be used.

3.1 Navigating the Remote's Menu

The ME-ARC has an internal structure that provides menu items and adjust-
able settings that provide the ability to confi gure your inverter/charger to
your specifi c parameters.
Info: See Figure 4-1, Inverter/Charger Menu Map for a complete
map of the inverter/charger menu items and adjustable settings.
Familiarize yourself with the items on the front panel which are used to fi nd,
adjust and save the desired setting. They are:
• LCD Display - The bottom line of the LCD display shows the menu items,
adjustable settings, or the meters display information.
Info: The bottom line of the LCD display returns to the Home Screen
to show DC voltage and current (see Figure 3-1) after 5 minutes - if
no buttons have been pressed.
Info: When the "←" (left facing arrow) symbol is shown on the
display it indicates that the displayed setting has been selected and
will be used.
Menu Pushbuttons (x5) - These fi ve buttons allow simple access to the
menu items that can help with confi guring, monitoring and troubleshooting
your inverter/charger system.
Rotary SELECT Knob - This knob allows you to quickly scroll through
and select various menu items and settings. Pushing on the knob selects the
menu item to change or saves this current selection. Refresh the LCD display
by holding this knob down for 7 seconds.
LCD
Display

Figure 3-1, Front Panel Set-up Features

© 2010 Magnum Energy, Inc.
Inverting
DC
12.6V
56A
Menu
Pushbuttons
3.0 Setup
Rotary
SELECT Knob