Magnum Energy ME-ARC Owner's Manual page 19

Table of Contents

Advertisement

http://www.wholesalesolar.com/inverter_systems.html
Manual Run: The generator has be started manually either from the
"03 Gen Control" menu or from a start/stop switch directly connected
to the generator.
No Comm: The ME-AGS-N is not communicating with the ME-ARC re-
mote. Causes could be a bad ME-AGS-N network cable, no power to the
ME-AGS-N, or there is no ME-AGS-N installed in the system.
Off: Generator is off and the AGS will not auto start the generator.
Quiet Time: The ME-AGS-N has entered Quiet Time as set in menu "04G
Quiet Time". The generator will not auto start during Quiet Time.
Ready: 03 Gen Control is set to Multi, and the ME-AGS-N is ready to
automatically start the generator based on the 04 AGS Setup settings.
Start Amp: The generator has started based on the settings in menu
"04C Gen Run Amps".
Start Exercise: The generator has started based on the settings in menu
"04H Gen Exercise".
Start SOC: The generator has started based on the settings in menu
"04D Gen Run SOC".
Start Temp: The generator has started based on the settings in menu
"04E Gen Run Temp".
Start Test: The ME-AGS-N is in the test mode. The test mode may be
started from the test button located on the ME-AGS-N (see the manual
for the ME-AGS-N for further information on the test button).
Start Time: The generator has started based on the settings in menu
"04B Gen Run Time".
Start Topoff: The generator has started based on the settings in menu
"04G Quiet Time".
Start VDC: The generator has started based on the settings in menu
"04A Gen Run VDC".
Fault Amp: The generator failed to start in the "Start Amps" mode.
Fault Exercise: The generator failed to start in the "Start Exercise"
mode.
Fault MaxRn: The generator exceeded Max Run Time and has turned
off.
Info: The generator will shut down when reaching the Max Run Time
and may still be running if this fault is observed.
Gen Run Fault: The generator successfully started and ran fro more
than 5 minutes, but unexpectedly stopped before the ME-AGS-N could
automatically stop the generator.
Fault SOC: The generator failed to start in the "Start SOC" mode.
Fault Temp: The generator failed to start in the "Start Temp" mode.
Fault Test: The generator failed to start in the "test" mode.
Fault Time: The generator failed to start in the "Start Time" mode.
Fault Topoff: The generator failed to start in the "Start Topoff" mode.
Fault VDC: The generator failed to start in the "Start VDC" mode.
© 2010 Magnum Energy, Inc.
3.0 Setup
15