Internal Fault Messages; Figure 5-33, Internal Bridge Fault; Figure 5-34, Internal Charger Fault; Figure 5-35, Internal Ntc Fault - Magnum Energy ME-ARC Owner's Manual

Table of Contents

Advertisement

http://www.wholesalesolar.com/inverter_systems.html

5.3.3.3 Internal Fault Messages -

The inverter continually monitors several internal components. If an condition
inside the inverter occurs that does not allow proper operation, the inverter
will shut down to help protect itself. To clear these "internal" type of faults,
the inverter will require an inverter reset.
Remedy: Perform an inverter reset; see section 6-2. After resetting
the inverter, press the ON/OFF INVERTER button to turn the inverter
on and verify the fault has cleared. If the "internal" fault remains, the
inverter will require repair at an authorized service facility.
PWR
Internal Bridge
FAULT
Settings/Info...
CHG
INV

Figure 5-33, Internal Bridge Fault

Internal Bridge – This fault message displays and the inverter shuts down
because the internal power-bridge protection circuit has been activated.
PWR
Internal Charger
FAULT
Settings/Info...
CHG
INV

Figure 5-34, Internal Charger Fault

Internal Charger - This fault message displays and the inverter shuts
down because the internal charger protection circuit has been activated.
PWR
Internal NTC
FAULT
Settings/Info...
CHG
INV

Figure 5-35, Internal NTC Fault

Internal NTC - This fault message displays and the inverter shuts down
because the internal NTC (temperature sensor) circuit has been activated.
PWR
Internal Relay
FAULT
Settings/Info...
CHG
INV

Figure 5-36, Internal Relay Fault

Internal Relay - This fault message displays and the inverter shuts
down because the internal AC transfer relay protection circuit has been
activated.
© 2010 Magnum Energy, Inc.
5.0 Operation
Internal Bridge appears on the LCD
and the FAULT (red) LED is on. The
PWR (green), CHG (green) and INV
(green) LED's are off.
Internal Charger appears on the
LCD and the FAULT (red) LED is on.
The PWR (green), CHG (green) and
INV (green) LED's are off.
Internal NTC appears on the LCD
and the FAULT (red) LED is on. The
PWR (green), CHG (green) and INV
(green) LED's are off.
Internal Relay appears on the LCD
and the FAULT (red) LED is on. The
PWR (green), CHG (green) and INV
(green) LED's are off.