Led Indicator Guide; Table 5-1, Led Indicator Guide - Magnum Energy ME-ARC Owner's Manual

Table of Contents

Advertisement

http://www.wholesalesolar.com/inverter_systems.html
5.0 Operation

5.3.4 LED Indicator Guide

The remote provides the following LED's; use them along with the LCD display
to determine the operating status.
LED
Status
OFF
PWR
(green)
ON
OFF
FAULT
(red)
ON
OFF
ON
BLINKING,
display says
"Charger
Standby".
BLINKING,
display says
CHG
"Full charge"
(green)
or "Silent".
BLINKING,
display shows
a charging
status (i.e.,
Bulk, Absorb,
Float).
BLINKING,
display does
not show any
charge status.
OFF
INV
ON
(green)
BLINKING
54

Table 5-1, LED Indicator Guide

1. Inverter is disabled; 2. Remote's in Power Save
mode - press any button to activate LED's; 3. No
power to remote (check remote cable or power
to inverter); or 4. No AC power at the inverter's
AC output terminals.
AC power is available from inverter, utility or
generator at the inverter's AC output terminals.
Normal operation.
A fault condition has been detected, check the
LCD display to fi nd and correct the cause.
1. Remote is in Power Save mode - press any
button to activate LED's; or, 2. Charger off - no
utility or AC generator present.
Bulk, Absorb, Float or Equalize charge mode (see
the LCD display to determine charge status).
The charger is in Charger Standby mode. This
occurs when the ON/OFF CHARGER button is
pressed to disable the charger.
The charger is in Battery Saver mode. This mode
monitors battery voltage level and only Charges
if the battery voltage decreases to a low level.
Silent mode will automatically start charging
when the ReBulk setting is reached.
The charger current is automatically decreased
because: 1. Charger Back-off - the inverter's
internal temperature is getting hot, current is
decreased to reduce/maintain temperature; or
2. Low AC Input Voltage - the input AC voltage
is <85 VAC, charger is disabled to help stabilize
incoming AC voltage to prevent AC disconnect.
The inverter is detecting AC voltage (from utility
or an AC generator) on the inverter's AC input
terminals.
1. Inverter is disabled; or, 2. Remote is in Power
Save mode - press any button to activate LED's
Inverter is enabled - 1. Supplying AC power
on the output; or, 2. In standby (if both INV
and CHG LED's are on); the inverter will
automatically supply AC power to the loads if
utility or generator power is lost.
Inverter is in Search mode (the AC load is below
the Setup 02A Search Watts setting).
© 2010 Magnum Energy, Inc.