Hayward OmniLogic Troubleshooting Manual page 28

Consumer network troubleshooting
Hide thumbs Also See for OmniLogic:
Table of Contents

Advertisement

2. Wi-Fi Connection: "MSP Not Found" (cont.)
Most networks run Dynamic (DHCP); this means the router issues the IP addresses to
connected devices. Static networks, although rare in residential applications, require
programmed IP credentials in order to connect to the router.
Verify the router is set to DHCP
Power cycle MSP and rescan
Step 2I
Step 2J
Mobile
Device
Router
Verify the router is issuing IP addresses. To get out to
On the MSP, power cycle the MSP
(steps on pg.
15).
the internet, if owner simply connects to the router,
When the OmniLogic boots back up, wait 3 minutes &
then it is DHCP. IF DHCP, go to step 2J. IF static, IP
rescan the network, entering the password. After 5
credentials must be provided to continue, contact the
minutes, IF an IP address appears go to step 2K. IF no IP
network administrator for this information.
address, go to 2L.
28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OmniLogic and is the answer not in the manual?

Questions and answers

JJ Till
February 20, 2025

CHLOR Relay K1 and K2 Stuck Closed Chlorinator alarm

1 comments:
Mr. Anderson
February 20, 2025

To fix the CHLOR Relay K1 and K2 stuck closed alarm on a Hayward OmniLogic system, try the following steps:

1. Power Cycle the System – Turn off the OmniLogic system, wait a few minutes, then turn it back on to see if the error clears.

2. Check for Physical Relay Issues – Inspect the relays for any visible damage or signs of burning.

3. Replace the 4A Fuse – If the error is intermittent, replacing the 4A fuse may help resolve the issue.

4. Update Firmware – Ensure the OmniLogic system is running the latest firmware, as updates may fix known issues.

5. Inspect Wiring and Connections – Verify that all wiring connections to the relays and T-Cell current sensor are secure and properly connected.

6. Monitor Error Behavior – If the error disappears and returns intermittently, it could indicate a failing relay that may need replacement.

If the issue persists after these steps, consider contacting Hayward support for further troubleshooting or relay replacement.

This answer is automatically generated