Chlorine generator for inground swimming pools up to 25,000 gallons (25 pages)
Summary of Contents for Hayward OmniPL HLBPRO4SW
Page 1
Pool Automation and Chlorination Operation Manual Contents Introduction........3 Bodies of Water......5 Favorites........19 Config........26 Simple Mode......34 Web Enabled Control....36 Warranty........38 HLBPRO4SW HLBPLUS4W Hayward Industries 400 Connell Drive, Suite 6100 Berkeley Heights, NJ 07922 Phone: (908) 355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 2
3 meters of the pool, spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 8 AWG US / 6 AWG Canada. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
System Info..............27 Backup Config..............27 Restore Config..............27 Display................. 28 Network............28 Date/Time...............28 Language............28 Data Log..............28 Upgrade Firmware............29 Service Mode Installing New Language..........31 Simple Mode Simple Mode..............34 Web Enabled Web Enabled Control............36 Control OmniPL Limited Warranty..........38 Warranty USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 4
This manual assumes that the OmniPL has been installed and configured according to the Installa- tion Manual and is using the latest firmware version available from Hayward. The OmniPL can now be programmed with user desired settings such as schedules, themes, and favorites. This manual will also explain how to manually turn pool equipment on/off, program settings for specific equipment, view pool equipment status and conditions, and more.
Features Off - Features Off offers a quick way to turn off all equipment with a single touch of a but- ton. Note that the filter pump, heater, lights and chlorination will continue to run if scheduled. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Bodies of Water regardless of which one is displayed. Up to four Favorite buttons will be shown on the home screen. To access more Favorites, touch the arrows to the left or right of the Favorite buttons. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Turn Off or Disable - This button will either manually turn off pool equipment or disable a function. Schedule - Touch this button to schedule a function. Countdown Timer - Touch this button to set a countdown timer. Back - Touch this button to return to a previous screen. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Control Screen which will let you manually turn on/off the pump, set a schedule, set a speed, apply a countdown timer and view the status. Single speed and two speed pumps will have a similar Control Screen. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 9
Touch the Add button (+) to add a schedule for the pool pump. ON/OFF start 10:00 am end 7:00 pm start / end repeat Please press + button to add schedule items. speed POOL POOL vsp pump vsp pump USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
NOTE: If you intend to run the pump at different speeds throughout the day, create additional sched- ules. You can start a new schedule on the same minute that the previous one ends. If schedules USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 11
Touch this Delete button to remove the schedule. Are you sure you want to delete the schedule? ON/OFF all week 10:00 am / 7:00 pm 10:00 am / 7:00 pm all week POOL vsp pump POOL vsp pump USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Body of Water. An example of the heater Control Screen is shown below: 1 / 2 set temperature 65 F 85 F actual alarm light row heater cleaner uclights chlorinator POOL POOL heater features Heater Control Screen USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Select Source Prioritize and disable that heater. A grayed out heater heater is disabled. heat pump Select Source Prioritize POOL heater heat pump set temperature POOL 65 F heater 85 F actual POOL heater USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Chlorinator Control Screen If using an HL-CHEM - The Hayward HL-CHEM Sense and Dispense accessory continuously tests the pool’s sanitization and pH levels allowing the OmniPL to automatically generate the correct amount of chlorine and dispense the proper amount of pH reducer. If using the HL-CHEM and ORP has been enabled in the Configuration Wizard, the OmniPL will display chlorinator readings and set- tings in “mV”...
Page 15
The chlorinator will turn off, wait for 15 seconds and then turn on in the opposite polarity. Reset Cell Maintenance Timer - To maintain maximum performance, it is recommended that you open and visually inspect the chlorinator cell every 3 months or after cleaning your filter. The OmniPL USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
500 hours of operation. You can restart the timer by touching this button. pH Dispense If using an HL-CHEM: The Hayward HL-CHEM Sense and Dispense accessory continuously tests the pool’s sanitization and pH levels allowing the OmniPL to automatically generate the correct amount of chlorine and dispense the proper amount of pH reducer.
Omni Direct mode. If so, the ColorLogic Control Screen will display a Settings icon rather than a Synchronize button, which allows both Speed and Brightness control shown on the diagram below. Note that Settings will also be an option when setting up schedules and timers for lights running USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Control Screen shown on the top of page 18. You can also set pump speed if a two-speed or variable speed pump has been configured to be used with the water feature. These functions have been illustrated previously in this manual. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Schedule Control Screen Spillover If spillover is configured, you can turn spillover on/off, set schedules, and set a countdown timer at the Spillover Control Screen. These functions have been illustrated previously in this manual. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
In most cases, touching a Favorite button on the Home Screen will bring you to the same screens that have been covered in the Control Screens section of this manual. Refer to these screens if necessary. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
These are the same Control Screens that you’ve used in the Body of Water Features and Controls Screen section of this manual. For Features, Lights and Heaters you can display the equipment based on a particular Body of Water or from all Bodies of Water. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 22
All of the buttons on the right side of the Home Screen are referred to as “Favorites” but there is also a Favorites button. Using this button, you can create and manage all of your Favorites. º con g lights jets deck lights MANAGE 71º F favorite favorites Manage Favorites Screen USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 23
Screen, from left to right. The default Favorites can not be moved. To move Favorites, follow the procedure below. heater uclights music chlorinator MANAGE favorites heater music uclights chlorinator MANAGE favorites heater music uclights chlorinator MANAGE favorites heater music uclights chlorinator MANAGE favorites USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 24
Simple Mode, moving the button location on the Favorites screen will affect its position on the Simple Mode screen. heater spillover uclights music MANAGE favorites music heater spillover uclights MANAGE favorites heater spillover music uclights MANAGE favorites heater lights spillover music MANAGE favorites USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 25
Theme. You pool party in the desired state. can now turn it on/off, edit, set a schedule, set a countdown timer, or delete the selection using the MANAGE buttons above. themes USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Theme within the “Manage Themes” screen follow the procedure below. Note that only one Theme can run at a time. pool party cozy spa MANAGE themes pool party cozy spa MANAGE themes º alarm themes 71º F daylight heater USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 27
The location of the USB port is shown in the Installation Manual. If a thumb drive will be used, follow the procedure on the top of page 27 when inserting and removing. WARNING - The thumb drive will always be inserted and removed with the power off. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Theme. System Info System Info will show the Hayward Unique Address (HUA) and version for all smart components (components that communicate with the OmniPL). This may be needed by Hayward Technical Ser- vice when troubleshooting or diagnosing system issues.
Data Log (requires Thumb Drive, page 26) Use this feature if instructed by Hayward Technical Service. The data log shows a log of daily op- eration and can help Hayward Technical Service diagnose or troubleshoot problems. The Data Log options are: Clear Log File- this will delete all data in the log file.
There may be a newer version available and if so, we encourage you to upgrade. Also, if you have experienced problems, Hayward Technical Support may advise you to upgrade your OmniPL firmware. If this is the case, follow the instructions below.
Page 31
R.3.0.4 SYSTEM INFO Using an ordinary web browser, go to www.hayward.com/firmware and compare the latest available version on the web to the current firmware version. If the firmware version on the web is greater (number is larger) than your current version, upgrade your OmniPL’s firmware.
WARNING - The thumb drive will always be inserted and removed with the power off. Locate the USB port on the OmniPL Controller and insert the thumb drive. Apply power to the OmniPL and allow enough time for the OmniPL to fully start. Enter Service Mode. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 33
12. Touch Save to begin upgrade. After the upgrade is finished, touch Save. ready to upgrade success ready to restart component firmware file component firmware file MSP_AR_R0103000-fr-CA MSP_AR_R0103000-fr-CA 100% UPGRADE UPGRADE firmware firmware USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 34
Wireless Waterproof - This option displays the HUA of each connected waterproof remote control and allows you to enable or disable the units. SC upload files - This option can be used to upload files to Hayward Technical Service for evaluation and troubleshooting.
Simple Mode will require your OmniPL’s MSP ID number. This number is used as a password. To find you unit’s MSP ID, refer to page 36. **** ENTER password service features simple shut down mode mode º alarm lights 71º F daylight favorites USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 36
Exit Simple Mode To exit Simple Mode, follow the procedure below. **** ENTER password service standard features shut down mode mode heating lights music spillover jets cleaner deck lights Twilight Gemstone Mardi Gras USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
OmniPL at any time from your browser by logging into your account at haywardOmniPL.com. For mobile devices, an application must be downloaded from your device’s app store. Go to www.hay- ward.com for more information on the availability and function of mobile apps. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 38
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
Page 39
Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years. Hayward also warrants its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for a period of one (1) year.