2. Wi-Fi Connection: "MSP Not Found" (cont.)
NOTE: When connecting to a your network from a Wi-Fi enabled device (such as a
smart phone) DO NOT connect to any 5Ghz networks as these are not supported by
the HLWLAN.
Connect a Wi-Fi enabled device
Check for IP address
Step 2G
Step 2H
On a Wi-Fi enabled device, connect to your network.
On the MSP, go to config>network. Verify the network
Run the Ookla app (speed test). IF speed is/above 3Mb
is set to Dynamic AND that an IP address appears under
for download & upload, go to 2H. IF lower than
'local IP', 'netmask, & 'gateway'*. IF IP address DOES
3Mb/3Mb, identify a location where speeds
NOT appear, go to 1I. IF IP address appears AND
consistently exceed 3Mb/3Mb & relocate the HLWLAN
registration is still unsuccessful, jump to step 2N to
to this location; then rescan & attempt registration.
determine why registration is still unsuccessful.
*NOTE: When the MSP is in Daylight mode and dynamic is selected it should have a grey
background.
27
Need help?
Do you have a question about the OmniLogic and is the answer not in the manual?
Questions and answers
CHLOR Relay K1 and K2 Stuck Closed Chlorinator alarm
To fix the CHLOR Relay K1 and K2 stuck closed alarm on a Hayward OmniLogic system, try the following steps:
1. Power Cycle the System – Turn off the OmniLogic system, wait a few minutes, then turn it back on to see if the error clears.
2. Check for Physical Relay Issues – Inspect the relays for any visible damage or signs of burning.
3. Replace the 4A Fuse – If the error is intermittent, replacing the 4A fuse may help resolve the issue.
4. Update Firmware – Ensure the OmniLogic system is running the latest firmware, as updates may fix known issues.
5. Inspect Wiring and Connections – Verify that all wiring connections to the relays and T-Cell current sensor are secure and properly connected.
6. Monitor Error Behavior – If the error disappears and returns intermittently, it could indicate a failing relay that may need replacement.
If the issue persists after these steps, consider contacting Hayward support for further troubleshooting or relay replacement.