Wm turf sprayer
Table of Contents

Advertisement

Figure 116
1. Flange-head bolt (1/4 x
3/4 inch)
2. Manifold valve (agitation
valve)
3. Valve mount
4. Flange locknut (1/4 inch)
3.
Remove the flange-head bolt (1/4 x 3/4 inch) and
flange locknut (1/4 inch) that secure the agitation
valve to the valve mount and remove the valve
manifold from the machine
Note:
Retain the flange head bolt, flange
locknut, and retainer for installation in
the Agitation Manifold Valve (page
g214596
5. Retainer
6. Quick-disconnect fitting
(socket)
7. Quick-disconnect fitting
(coupling)
(Figure
116).
Installing
85).
Removing the Master Boom
Manifold Valve
1.
Remove flange clamps and gaskets that secure
the manifold for the master-boom valve
117) to the master-boom bypass valve, agitation
valve, and 90° flanged elbow (at the end of the
hose for the flow meter).
Note:
Retain the flange clamps and gaskets
for installation in
Manifold Valve (page
1. Flange (agitation-valve)
2. Flange
(bypass—master-boom
valve)
3. Manifold (master-boom
valve)
2.
Remove the retainer that secure the 90°
outlet fitting to the manifold coupling for the
master-boom valve
80
Installing the Master Boom
86).
Figure 117
4. Flange clamp
5. Gasket
6. 3-pin connector (valve
actuator—master-boom
valve)
(Figure
118).
(Figure
g033590