Removing the Valve Actuator
1.
Position the sprayer on a level surface, engage
the parking brake, shut off the pump, shut off the
engine, and remove the key.
2.
Remove the 3-pin connector of the valve
actuator from the 3 socket electrical connector
of the sprayer harness.
3.
Remove the retainer that secures the actuator to
the manifold valve for the rate control, agitation,
master section, or section valve
Note:
Squeeze the 2 legs of the retainer
together while pushing it down.
Note:
Retain the actuator and retainer for
installation in
Installing the Valve Actuator (page
88).
Figure 112
Section-Valve Actuator Shown (the agitation-valve actuator
1. Valve actuator (section
valve shown)
2. Retainer
4.
Remove the actuator from the manifold valve.
(Figure
is similar)
3. Stem port
Removing the Rate Control
Manifold Valve
1.
Remove 2 flange clamps and 2 gaskets that
secure the manifold for the rate control valve
(Figure
valve.
Note:
for installation in
Manifold Valve (page
112).
1. Flange (pressure filter
g028237
head)
2. Manifold (rate control
valve)
3. Flange (agitation valve)
2.
Remove the retainer that secure the outlet fitting
to the manifold coupling for the rate control valve
(Figure
78
113) to the pressure filter and agitation
Retain the flange clamps and gaskets
Installing the Rate Control
84).
Figure 113
4. Flange clamp
5. Gasket
6. 3-pin connector (valve
actuator—rate control
valve)
114).
g033584