Toro Multi Pro 41240 Operator's Manual page 79

Wm turf sprayer
Table of Contents

Advertisement

Figure 114
1. Flange-head bolt (1/4 x
3/4 inch)
2. Valve mount
3. Flange locknut (1/4 inch)
3.
Remove the 2 flange-head bolts (1/4 x 3/4 inch)
and 2 flange locknuts (1/4 inch) that secure
the rate control valve to the valve mount and
remove the valve manifold from the machine
(Figure
114).
Note:
If necessary, loosen the mounting
hardware for the pressure filter head to ease
removal of the rate control valve.
Note:
Retain the flange-head bolts, flange
locknuts, and retainer for installation in
the Agitation Manifold Valve (page
g033585
4. Retainer
5. Socket (outlet fitting)
6. Coupling (manifold—rate
control valve)
Installing
85).
Removing the Agitation Manifold
Valve
1.
Remove 3 flange clamps and 3 gaskets that
secure the manifold for the agitation valve
(Figure
115) to the agitation bypass valve, rate
control valve, and master-boom valve.
Note:
Retain the flange clamps and gaskets for
installation in
Valve (page
85).
1. Flange (pressure filter
head)
2. Manifold (agitation valve)
3. Flange (bypass
valve—agitation valve)
4. Flange clamp
2.
Remove the retainer that secure the
quick-disconnect socket to the manifold
quick-disconnect coupling for the agitation valve
(Figure
116).
79
Installing the Agitation Manifold
Figure 115
5. Gasket
6. 3-pin connector (valve
actuator—agitation valve)
7. Flange (master-boom
valve)
g033586