Chapter 9 Maintenance and service

Weekly servicing (after appr. 40 hours of operation)

Requirements
Labeler is without electrical power.
No transportation of products.
Required equipment
Alcohol (*21800915) or roller solvent (*21800977)
Lint-free cloth (*21800978)
Label remover (*21800771)
* Product recommendation. Can be obtained from the Bluhm Weber Group with the eight-character article number.
Instruction
Please arrange the weekly maintenance as follows.
Step
1
2
3
4

Annual servicing (after appr. 2000 hours of operation)

Requirements
Labeler is without electrical power.
No transportation of products.
Required equipment
Bearing grease Proline, Pro 672U (92100772, food compliant)
* Product recommendation. Can be obtained from the Bluhm Weber Group with the eight-character article number.
Instruction
Please arrange the yearly servicing as follows.
Step
1
2
Version: 30.07.14
Procedure
Clean surface of peeler plate and all paper guiding parts from adhesive using
label remover or alcohol.
Clean all sensors (product sensor, low label warning sensor, label gap
sensor) carefully with a cloth.
Examine all pipe connections for tightness and leakage.
Examine all roller assemblies for free rotation and correct position of the
rollers` axes.
Procedure
Replace all that is necessary for proper function.
Examine all moving parts for loose connections and possible wear
(bearing clearance).