Chapter 7 Adjustment and initial operation

Adjust peeler plate

The peeler plate of top side labeling has to be adjusted on distance and position to the
product. Use the adjusting device of the labeler.
Information on adjustment of peeler plate
The peeler plate has to be adjusted on a distance of approx. 1-3 mm to the product (no
product contact) via traverse adjustment of the labeler (no product contact). The peeler
plate should be installed in an angle of 15°-30° to product.
The required label position on the product is adjusted by lateral adjustment of the labeler.
No.
1
2
3
4
5
Requirements
¥
Side guidance is correctly adjusted (s. page 37).
¥
Labeler is switched on and ready.
¥
One or more sample products.
¥
No transportation of products.
Version: 30.07.14
Description
CRANK FOR HEIGHT ADJUSTMENT
CRANK FOR SIDE ADJUSTMENT
CLAMPING FOR ANGLE ADJUSTMENT
PEELER PLATE
SAMPLE PRODUCT
Page 41 of 57
40001136 Geset 125
Fig. 7-8: Adjust peeler plate