Electrical Requirements - Model SLX400E ONLY

1. Always verify electrical specifications
on the data plate (figure 4-1) of
each individual freezer. Data plate
specifications will always supersede
the information in this manual.
2. This freezer requires a protected 20
amp 220 volt circuit. Connect the
freezer to a circuit separate from
any other electrical equipment. The
freezer plug will fit a NEMA 6-20R
receptacle. See figure 2-3.
2.5

Electrical Connections

1. Freezer requires one power supply.
Always check the data plate for proper
fuse size, wire ampacity, and electrical
specifications.
2. Refer to the wiring diagram provided
for proper power connections.
3. Electrical connections for models
SLX500 are made in a junction box.
Facing the front of the freezer it is
located behind the right side panel
towards the back and bottom of the
frame.
4. The Model SLX400E is supplied with
a cord, a NEMA 6-20P plug that plugs
into a 6-20R receptacle. See Figure
2-3.
4
CAUTION
To prevent accidental electrical
shock, a receptacle with
a positive earth ground is
required.
CAUTION
To prevent accidental electrical
shock, a positive earth ground
is required.
3. Supply voltage must be within ±10%
of voltage indicated on the nameplate.
4. An easily accessible main power
disconnect must be provided for all
poles of the wiring to the freezer.
Figure 2-3 Plug
4. Use a flexible connection when
permissible. Copper wires are
required for connection to freezer.
All materials and connections must
conform to local codes and/or the
National Electrical Code.
5. For all 3 phase freezers, beater shaft
rotation must be clockwise as viewed
from the front of the freezer.