Operation View - Gree U-MATCH Series Service Manual

Dc inverter air conditioners
Hide thumbs Also See for U-MATCH Series:
Table of Contents

Advertisement

U-Match Series DC Inverter Service Manual

3.2 Operation View

3.2.1 Silk Screen of Buttons
3.3.2 Instruction to Function of Buttons
No.
Description
1
Enter/Cancel
2
6
3
4
Mode
5
Function
7
Timer
8
On/Off
4 Mode
and
Memory function
2 ▲
2 ▲
and
Lock
6 ▼
4 Mode
Enquiry and setting
and
of address of wired
5 Function
controller
Setting of project
5 Function
parameters (More
and
details please refer
7 Timer
to the Notes)
4 Mode
Switch between
and
Fahrenheit and
6 ▼
Centigrade
5 Function
Viewing historical
and
malfunction
6 ▼
1 Enter/
Setting of master
Cancel and 4
and slave wired
Mode
controller
Figure 2-3-3 Silk screen of buttons
Table 2-3-2 Instruction to buttons of wired controller
(1)Function selection and canceling;
(2) Press it for 5s to view the ambient temperature; press Mode button to select
viewing outdoor ambient temperature or indoor ambient temperature.
(1) Running temperature setting range of indoor unit: 16-30℃;
(2) Timer setting range: 0.5-24hr;
(3) Setting of air function level;
(4) Setting of energy-saving temperature;
(5) Setting of cleaning class.
Fan
Setting of high/medium high/medium/medium low/low/auto fan speed.
Setting of auto/cooling/heating/fan/dry mode of indoor unit.
Switch over among these functions of swing/ air/ sleep/ health/ I-Demand/
out/turbo/ save/ e-heater/ X-fan/ clean/ quiet.
Timer setting.
Turn on/off indoor unit.
Press Mode and ▲ buttons at the same time for 5s under off state of the unit to
enter/cancel memory function (If memory function is set, indoor unit will resume
original setting state after power failure and then power recovery. If not, indoor
unit is defaulted to be off after power recovery. Ex-factory setting of memory
function is on).
Upon startup of the unit without malfunction or under off state of the unit, press
▲ and ▼ buttons at the same time for 5s to enter lock state. In this case, any
other buttons won‟t respond when pressing. Repress ▲ and ▼ buttons for 5s to
quit lock state.
Under off state of the unit, press Mode and Function buttons at the same time for
5s to set the address. (More details please refer to project debugging)
Under off state of the unit, press Function and Timer buttons at the same time for
5s to go to the debugging menu. Press Mode button to adjust the setting items
and press ▲ or ▼ buttons to set the actual value.
Under off state of the unit, press Mode and ▼ buttons at the same time for 5s to
switch between Fahrenheit and Centigrade.
Continuously press Function and ▼ buttons for 5s to view historical malfunction.
Then press ▲ and ▼ buttons to adjust displayed contents. The timer displaying
position displays the sequence of malfunction and the detailed error code. The
5th displayed malfunction is the last malfunction.
Under off state of the unit, press Enter/Cancel and Mode buttons at the same
time for 5s to set master and slave wired controller. Press ▲ or ▼ button to
Functions
adjust. (More details please refer to project debugging)
20