2. Remove the water tray
3. Loosen the bolts fixing
the fan
4. Remove the fan
5. Loosen the screws
fixing the motor
6. Remove the motor and
replace it
7. Tighten the screws
fixing the motor
U-Match Series DC Inverter Service Manual
Remove the water tray.
Use spanner to loosen the bolts fixing
the fan.
Remove the fan.
Use screwdriver to loosen the screws
fixing the motor.
Remove the motor and replace it.
Use screwdriver to tighten the screws
fixing the motor.