Gree U-MATCH Series Service Manual page 91

Dc inverter air conditioners
Hide thumbs Also See for U-MATCH Series:
Table of Contents

Advertisement

U-Match Series DC Inverter Service Manual
 F1 Malfunction of Evaporator Temperature Sensor
 F2 Malfunction of Condenser Temperature Sensor
Malfunction of
evaporator
temperature
sensor
Check if the evaporator
temperature sensor on
mainboard is inserted on the
needle stand correctly
Yes
Disconnect
the temperature sensor and
measure if its resistance is
normal
Yes
Replace the
indoor
mainboard
Malfunction of
condenser
temperature
sensor
Check if the condenser
temperature sensor on
mainboard is inserted on the
needle stand correctly
Yes
Disconnect
the temperature sensor and
measure if its resistance is
normal
Yes
Replace the
outdoor
mainboard
Correctly insert the
temperature
No
sensor on the
needle stand
Replace the
No
temperature
Correctly insert the
No
temperature sensor
on the needle stand
No
Replace the
temperature sensor
88
sensor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents