U-Match Series DC Inverter Service Manual
7.2.7 Reserved fresh air valve interface for duct type unit
For the reserved connection way of air valve performer, connect it to F, C, O of wiring board
according to the wiring diagram. Connect the public port of air valve to F, connect CLOSE to C and
connect OPEN to O.
7.2.8 Interface of anion generator
For the cold plasma anion generator, connect the red line to HEALTH(X4) and the blue line to
N2(X6) according to the principle circuit. The detector of cold plasma anion generator should be places
at the air return. The distance between two detectors should be 10mm≤L≤25mm.