Gree U-MATCH Series Service Manual page 110

Dc inverter air conditioners
Hide thumbs Also See for U-MATCH Series:
Table of Contents

Advertisement

36/42k
Disassembly and Assembly of external casing
Remark :
Step
1. Remove external casing
2. Remove motor
3.
Remove
gas
separator
4. Remove compressor
Illustration
liquid
U-Match Series DC Inverter Service Manual
Handling Instruction
1. Remove the top cover and handle;
2. Remove the grille, outer case and
right side plate.
1. Remove the blade nut and then
remove the blade;
2. Remove the motor from motor
support.
1. Discharge the refrigerant inside the
pipeline and recycle the refrigerant
during discharging;
2. Unsolder the 4-way valve assy
from gas liquid separator;
3. Remove the gas liquid separator.
1. Discharge the refrigerant inside the
pipeline and recycle the refrigerant
during discharging;
2. Unsolder the 4-way valve assy
from compressor;
3. Remove the nut fixing compressor;
4. Take away the compressor from
chassis.